Chapter I

General Plumbing Knowledge and Regulations

Content area 1 of the Oklahoma master plumber exam.

General Knowledge of the Plumbing Code

Reference text for the general knowledge area. Each rule below is stated from the printed line of the

2024 International Plumbing Code (IPC 2024) that carries it, and names the section it comes from.

Numbers appear only where the printed line carries them.

What this area asks for is knowledge of the code itself rather than of one of its technical chapters,

and the corpus carries that knowledge in two places: Chapter 1, whose subject is the limits within

which the code applies and the way it is applied and enforced, and Chapter 2, whose subject is what

the code's terms mean for the purposes of the code (IPC 2024, Chapter 1 and Chapter 2). The map of

the chapters and appendices below is the one the corpus itself prints. The running of the code inside

a jurisdiction — its enforcing department, permits, fees, inspections and appeals — belongs to

Sections 103 through 115 of Chapter 1 and is deliberately outside this text; only the general

applicability of the code (Sections 101 and 102) and its definitions are treated here.

1. The code, its scope and its purpose

The code takes the name of the jurisdiction that adopts it and is called "this code" thereafter. The

printed line carries a placeholder where that name belongs, so no name appears here (IPC 2024, 101.1).

Scope covers a plumbing system's whole life inside the jurisdiction: putting it up, installing it,

altering it, repairing it, relocating it, replacing it, adding to it, using it, maintaining it

(IPC 2024, 101.2). Certain systems that are plumbing for this purpose are named in the same breath —

nonflammable medical gas, inhalation anesthetic, vacuum piping, nonmedical oxygen systems, and

sanitary and condensate vacuum collection systems. Two families of work are handed to another

document: fuel gas distribution piping and equipment, fuel-gas-fired water heaters, and water heater

venting systems belong to the International Fuel Gas Code (IPC 2024, 101.2). One exception opens a

second path for small residential work: detached one- and two-family dwellings and townhouses up to

three stories above grade plane with a separate means of egress, together with their accessory

structures of the same height limit, may comply with this code or with the International Residential

Code (IPC 2024, 101.2).

Appendices are inert until adopted: their provisions apply only where a jurisdiction adopts them

specifically (IPC 2024, 101.2.1).

Purpose is stated as a minimum standard — safety, health, protection of property and general welfare

at a reasonable level, obtained by regulating the design and the construction, the installation, the

quality of materials, the location, and the operation, maintenance or use of plumbing equipment and

systems (IPC 2024, 101.3).

Severability keeps the rest of the code standing if one part falls: holding a section, subsection,

sentence, clause or phrase unconstitutional does not touch the validity of the remaining portions

(IPC 2024, 101.4).

2. How the code applies

2.1 General against specific

Two requirements that disagree are settled by rank, not by preference: the specific requirement beats

the general one, and where different sections of the code offer different materials, methods of

construction or other requirements for one case, the most restrictive governs (IPC 2024, 102.1).

2.2 Work already in place

A plumbing system that was lawfully in existence when the code was adopted may keep being used and

maintained, on two conditions — its use, maintenance or repair follows the original design, and it

creates no hazard to life, health or property (IPC 2024, 102.2). Where the work concerns building or

structural matters rather than plumbing, additions, alterations, renovations and repairs fall to the

International Existing Building Code (IPC 2024, 102.2.1).

2.3 Maintenance is the owner's

Existing and new plumbing systems, their materials and appurtenances, and every part of them, are

kept working as designed and in a safe and sanitary condition; devices or safeguards the code requires

stay in compliance with the edition of the code they were installed under. Responsibility rests with

the owner or the owner's authorized agent, and the code official may require any plumbing system to be

reinspected to check that compliance (IPC 2024, 102.3).

2.4 Additions, alterations and repairs

New work on an existing system is held to the standard of a new plumbing system, but the code does not

use that to drag the whole existing system into compliance; what it forbids is leaving an existing

system unsafe, unsanitary or overloaded (IPC 2024, 102.4). Minor work is treated as new construction

unless it repeats the manner and arrangement already there, is not hazardous and is approved

(IPC 2024, 102.4).

2.5 Change of occupancy

A change of occupancy that brings a structure under a special provision of the code for the new

occupancy needs the code official's approval. Certification is then the official's: that the structure

meets the intent of the law governing building construction for the proposed occupancy, and that the

change creates no hazard to public health, safety or welfare (IPC 2024, 102.5).

2.6 Historic and moved buildings

Buildings identified and classified as historic by the state or local jurisdiction are released from

the code's construction, alteration, repair, enlargement, restoration, relocation and moving

provisions where the code official judges them safe and in the public interest of health, safety and

welfare for the work proposed (IPC 2024, 102.6). A building moved into or within the jurisdiction is a

different case: its plumbing systems must meet the code's provisions for new installations, except

where Section 102.2 decides otherwise (IPC 2024, 102.7).

3. The code and the documents it references

The referenced codes and standards are the ones listed in Chapter 15, and they form part of the code's

requirements to the extent each reference reaches, subject to the two rules that follow (IPC 2024,

102.8). Where the code and a referenced standard disagree, the code wins (IPC 2024, 102.8.1). Where a

reference reaches subject matter that the code itself covers, the code's provisions take precedence

over the referenced document's (IPC 2024, 102.8.2).

Three closing rules of this section settle what is not written down. Requirements for strength,

stability or proper operation of a system, or for public safety, health and general welfare, that the

code does not specifically cover are determined by the code official (IPC 2024, 102.9). No provision

of local, state or federal law is nullified by the code (IPC 2024, 102.10). And a reference to a

chapter or section number, or to a provision the code does not identify by number, is read as a

reference to that chapter, section or provision (IPC 2024, 102.11).

4. Reading the code through its definitions

Chapter 2 is where the terms used in the body of the code are defined, and those meanings govern

unless the code expressly states otherwise (IPC 2024, 201.1). The corpus gives the reason the chapter

exists: a code is technical writing, in which a single word, term or punctuation mark can enlarge or

narrow a requirement, and a shared understanding of each term is what holds the interpretation

together (IPC 2024, Chapter 2).

The chapter also carries rules for reading the text. Words in the present tense reach into the future;

masculine wording includes the feminine and the neuter; the singular includes the plural and the

plural the singular (IPC 2024, 201.2).

Terms the code leaves undefined are resolved in two steps. Where the term is defined in the

International Building Code, the International Fire Code, the International Fuel Gas Code or the

International Mechanical Code, it carries the meaning given there (IPC 2024, 201.3). Failing that,

the term means what it ordinarily means, as its context implies (IPC 2024, 201.4).

5. The working vocabulary of the code

The terms below are the ones the technical chapters lean on. They are given in the sense of Section

202 of the code (IPC 2024, 202).

TermSense in which the code uses it (IPC 2024, 202)
ApprovedAcceptable to the code official.
Approved agencyAn established, recognized organization that regularly conducts tests or furnishes inspection services, or furnishes product evaluation or certification, and is approved by the code official.
Code officialThe officer or other designated authority charged with administering and enforcing the code, or a duly authorized representative.
Accepted engineering practiceThat which conforms to principles, tests or standards accepted by nationally recognized technical or scientific authorities.
PlumbingThe practice, materials and fixtures used to install, maintain, extend and alter piping, fixtures, plumbing appliances and plumbing appurtenances inside or beside a structure, where they serve sanitary or storm drainage, venting, or a public or private water supply.
Plumbing fixtureA receptacle or device tied to a water supply system, to a drainage system, or to both: it needs a supply of water, or it discharges liquid or liquid-borne solid waste, or it does both.
Potable waterWater whose impurities stay below the amounts that cause disease or harmful physiological effects, and which meets the bacteriological and chemical quality requirements of the Public Health Service Drinking Water Standards or of the public health authority having jurisdiction.
Water supply systemThe water service pipe, the water distribution pipes, and the connecting pipes, fittings, control valves and appurtenances inside or beside the structure or premises.
Water mainA water supply pipe, or a system of pipes, installed and maintained by a city, township, county, public utility company or other public entity, on public property, in the street, or in an approved dedicated easement of public or community use.
Cross connectionA physical connection or arrangement between two otherwise separate piping systems — one carrying potable water, the other carrying water of unknown or questionable safety, or steam, gas or chemical — where flow from one system into the other is possible, its direction being set by the pressure difference between them.
BackflowWater or another liquid, mixture or substance entering the distribution pipes of a potable supply from a source other than the intended one. The code separates the condition into three parts. Low-head backpressure is a pressure of 4.33 psi (29.88 kPa) or less, which is the pressure a 10-foot (3048 mm) column of water exerts. Backsiphonage is contaminated water reaching the potable system because pressure there drops below atmospheric at the fixtures, pools, tanks or vats tied to the potable distribution piping. Backflow in drainage is a reversal of flow in the drainage system.
Building drainThe lowest piping of a drainage system, taking the discharge of the soil, waste and other drainage pipes inside the building and running 30 inches (762 mm) of developed length beyond the exterior walls on its way to the building sewer.
Building sewerWhat continues from the end of the building drain and carries the discharge to a public sewer, a private sewer, an individual sewage disposal system or another point of disposal.
Soil pipeA pipe carrying sewage that contains fecal matter to the building drain or building sewer.
WasteDischarge from a fixture, appliance, area or appurtenance with no fecal matter in it.
Drainage fixture unitA measure of the discharge a plumbing fixture is likely to put into the drainage system; the value for a given fixture follows from the rate at which it drains, how long one draining operation lasts, and the usual interval between one operation and the next.
Fixture drainThe pipe from a fixture's trap to the point where it joins another drain pipe.
Fixture branchA drain that serves two or more fixtures and discharges into another drain or into a stack.
StackAny vertical run of soil, waste, vent or inside conductor piping passing through one story or more, with or without offsets.
Vertical pipeA pipe or fitting set at 45 degrees (0.79 rad) or more from horizontal.
TrapA fitting or device whose liquid seal keeps sewer gases from escaping, without getting in the way of the sewage or wastewater flowing through it.
Trap sealThe vertical distance from the weir to the top of the trap's dip.
Flood level rimThe edge of a receptacle over which water spills.
CleanoutAn access opening in the drainage system for removing obstructions; a removable plug or cap and a removable fixture or fixture trap are among its forms.
Air gap, drainage systemThe vertical distance, unobstructed and through free atmosphere, from the waste pipe's outlet down to the flood level rim of the receptacle it discharges into.
Air gap, water distribution systemThe vertical distance, unobstructed and through free atmosphere, from the lowest opening of any pipe or faucet supplying water to a tank, fixture or other device down to the flood level rim of the receptacle.
Air break, drainage systemAn arrangement in which a fixture, appliance or device drain discharges indirectly into another fixture, receptacle or interceptor, below the flood level rim and above the trap seal.
Indirect waste pipeA waste pipe that discharges into the drainage system through an air break or air gap into a trap, fixture, receptor or interceptor instead of connecting to it directly.
Developed lengthDistance along the centerline of pipe and fittings.
Ready accessReaching a fixture, appliance or equipment directly, with no panel or similar obstruction removed or moved and without a portable ladder, step stool or the like.
Individual ventA pipe venting one fixture trap, connected to the vent system above the fixture it serves or ending in open air.
Common ventA vent that joins at the junction of two fixture drains, or to a fixture branch, and vents both fixtures.
Stack ventA soil or waste stack continued above the highest horizontal drain connected to it.
Vent stackA vertical vent pipe whose main job is moving air to and from any part of the drainage system.
Relief ventA vent whose main job is air circulation between the drainage and vent systems.
Combination waste and vent systemWaste piping designed as one system, wet-venting one or more sinks, lavatories, drinking fountains or floor drains horizontally through a common waste and vent pipe sized so air moves freely above the flow line of the drain.
Area drainA receptacle built to collect surface or storm water from an open area.
OffsetApproved bends arranged so that one section of pipe leaves the line and returns parallel to it.

6. The reach of each chapter

The corpus prints, chapter by chapter, what each one is for. That description is the map of the code

(IPC 2024, Chapter 1).

ChapterWhat the corpus says it governs (IPC 2024, Chapter 1)
1The limits of the code's applicability and the manner of its application and enforcement, in two parts: scope and application (Sections 101 and 102) and administration and enforcement (Sections 103 through 115).
2The definitions of the terms used in the body of the code — read in the light of the reason the corpus gives, that the definitions are essential to interpreting the code and that a reader may not realize a term is defined at all.
3The safety requirements for installing plumbing and nonplumbing fixtures of every kind.
4The materials, design and installation of plumbing fixtures, faucets and fixture fittings according to the occupancy, with the minimum number of fixtures for each type of occupancy.
5The design, approval and installation of water heaters and of the safety devices that go with them, so as to reduce the hazards of their installation and operation.
6Bringing potable water from public and individual sources to every fixture and outlet without losing its potability, and designing the distribution system so fixtures work properly and backflow is prevented.
7The materials, design and installation of sanitary drainage piping and the connections made to it, so that drainage systems work reliably, are neither too small nor larger than needed, and are built of the materials, fittings and connections the code prescribes.
8Drainage installations that need an indirect connection to the sanitary drainage system — fixtures and appliances tied to food preparation and handling, to health care facilities and to potable liquids, which must be shielded from the contamination a direct connection to drainage can bring.
9Vents and venting, whose purpose is to keep every trap from losing its seal.
10The design requirements and installation limits for traps, and the design and location of the several kinds of interceptors and separators.
11Removing storm water, done properly so that a flat roof cannot collapse structurally and footings and foundations are not damaged.
12Designing, installing, storing, handling and using nonflammable medical gas systems, including inhalation anesthetic and vacuum piping, bulk oxygen storage, and oxygen-fuel gas systems for welding and cutting.
13Designing and installing nonpotable water systems, rainwater harvesting among them.
14Designing and installing subsurface graywater soil absorption systems that dispose of on-site nonpotable water such as graywater.
15The product and installation standards and codes referenced in Chapters 1 through 14, with the bodies that promulgate them and the sections that reference them — and, as Section 102.8 provides, those documents become enforceable as part of the code to the extent each reference reaches, as though printed in the body of the code.

Two rules from Section 101 close the map. What the code requires is a minimum and a reasonable level

of safety, health, property protection and general welfare — not a guarantee (IPC 2024, 101.3). And

among requirements that disagree, the more specific, and then the most restrictive, governs

(IPC 2024, 102.1).

State Law and the Licensing Board

Reference text for the state law and board area. This is the only matter of this set that is not

written from the International Plumbing Code: the code corpus carries nothing about a state's licence

law or its board, so nothing here is taken from it. Every rule below is written from a document filed

in this repository, and each rule names that document and the line it was read on. Section 8 names what

was looked for and is not there; no rule is stated below that cannot be read on a line of one of these

pieces.

The pieces, and the short form each is cited by:

docs/blueprints/OK/OK-748-20-16-permanent-rule-2024-IPC.txt — the OUBCC adopted-code rule captured as

text from the PDF of the same name — cited below as 748-rule.

docs/blueprints/OK/OK-CIB-PSI-bulletin.txt — the CIB/PSI candidate information bulletin captured as

text from OK-CIB-PSI-bulletin.pdf — cited below as CIB-bulletin.

docs/blueprints/OK/BULLETIN.md and docs/blueprints/OK/PROVENANCE.md — the repository's digest and

provenance note, cited by file name.

1. The board and the code it adopts

Title 748 is the Oklahoma Uniform Building Code Commission (OUBCC), Chapter 20 its adopted codes, and

Subchapter 16 its adoption of the International Plumbing Code, 2024 edition, running 748:20-16-1

through 748:20-16-20 (748-rule, l. 1). The 2024 first printing of June 2023, as amended and modified

in that subchapter, is adopted as the statewide minimum code for commercial plumbing construction in

Oklahoma under 59 O.S. 1000.23 (748-rule, l. 37); by the same formal action the commission chose not

to adopt the 2021 edition for any purpose (748-rule, l. 42); and the adoption takes effect September

14, 2026 as the permanent rule under OAC 748:20-16-1 (748-rule, l. 19).

Everything the subchapter does not specifically address as modified, deleted, moved or removed —

chapters, provisions within chapters and exceptions — is adopted without modification; the adopted code

may only be amended by other jurisdictions under Oklahoma law and the commission's rules in Title 748,

Chapter 15 (748-rule, l. 66 and l. 50).

2. Appendices, and who else may adopt

No appendix of the IPC 2024 was adopted by the commission for the statewide minimum code (748-rule,

l. 58). Appendices A through F and Resource A are not adopted, but other jurisdictions in Oklahoma may

adopt any or all of them under 59 O.S. 1000.29 (748-rule, l. 61): an appendix is not state minimum

code, and a requirement drawn from an appendix is a local requirement.

3. How to read "Reserved" and "Revoked"

The document states what its markers mean, and both keep the chapter. "Revoked" means the modifications

of Oklahoma's earlier adoption are withdrawn and the language reverts to the published content of the

adopted code without amendment (748-rule, l. 9). "Reserved" means no modifications were made to that

chapter, which stands as published as part of the statewide minimum code (748-rule, l. 14). In practice

the indirect and special waste chapter appears as a revoked 2018-era entry, so its rule is the

published 2024 text (748-rule, l. 362), and two subchapter sections — 748:20-16-10 and 748:20-16-17 —

carry the single word "Reserved" and no modification (748-rule, l. 313).

4. What the board did modify

The amendments sit one rule section per code chapter. Chapter 6 adds the IAPMO Water Demand Calculator

as an approved alternate method of determining system water demands in place of the standard Chapter 6

value (748-rule, l. 323), and adds an exception for domestic dishwashers and drinking fountains whose

fixture supply pipe must be not more than 72 inches (1829 mm) from the point of connection to the

fixture (748-rule, l. 329). Chapter 7 modifies the PVC solvent-cementing provision by removing the words "both of" from

its exception, so that the exception reads as three conditions rather than a pair (748-rule, l. 347).

One amendment reaches an area of this set directly: the nonpotable water chapter requires a cleanout on

each overflow pipe in accordance with the code's cleanouts section (748-rule, l. 415).

5. The licence and the scope of work it carries

The bulletin's scope-of-work statement is the same for the plumbing contractor and the plumbing

journeyman: installation, repair and maintenance or extension of any plumbing system — sanitary

drainage waste and vents, water supply, plumbing fixtures, roof drains — plus gas piping, appliances,

vents, flues, tanks and related appurtenances, in a supervised environment (CIB-bulletin, l. 2397 and

l. 2532). Passing produces the licence: on passing the licence exam, the Oklahoma State Construction

Industries Board issues the licence (CIB-bulletin, l. 292). The score appears on screen at the end of

the time allowed, and a candidate who does not pass receives a diagnostic report of strengths and

weaknesses by examination type (CIB-bulletin, l. 281).

6. The examinations, as the bulletin prints them

ExaminationQuestionsPassing %Passing (raw)Time allowed
Plumbing contractor and natural gas857564180 minutes
Plumbing journeyman and natural gas857564180 minutes
Residential journeyman plumbing and natural gas85 scored items75—180 minutes
Residential contractor plumbing and natural gas85 scored items75—180 minutes
Plumbing business and law507537120 minutes

The contractor and journeyman rows are read from those two examinations' own tables, the two

residential plumbing examinations from the heading line giving item count, time and passing

percentage, and the business and law examination from its own line (CIB-bulletin, l. 2408 and l. 2542;

l. 2587 and l. 2664; l. 2305).

The contractor and journeyman examinations share one topic list with an item count each: General

Plumbing Knowledge and Regulations 10; Piping, Valves, and Control Valves 8; Fixtures and Equipment 8;

Water Supply 10; Drains and Sewers 10; Vents 13; Traps, Interceptors, Indirect, and Special Waste 5;

Isometric Analysis 7; Fuel Gas 10; Safety 4 (CIB-bulletin, l. 2411). The business and law examination

carries eight topics with item counts, from Bidding and Estimating 10 through Licensing Requirements 6

(CIB-bulletin, l. 2310).

7. The references, the conflict rules and the exam room

The bulletin lists the references used to prepare the questions, states that an examination may also

contain questions based on trade knowledge or general industry practices, and states that for code

questions the examinations are based only on the edition of the code book listed (CIB-bulletin,

l. 2197). For the plumbing contractor examination those references are the International Plumbing Code,

2018 edition, with Oklahoma Revisions; the International Fuel Gas Code, 2018 edition, with Oklahoma

Revisions; Mathematics for Plumbers and Pipefitters, 8th edition, 2013; and 29 CFR Part 1926 (OSHA)

(CIB-bulletin, l. 2470). For the business and law examination they are the Construction Industries

Board's unofficial administrative rules and exam study aids book; the Oklahoma Plumbing License Law of

1955 (Oklahoma Statutes, Title 59, Chapter 27); the Oklahoma Plumbing Industry Regulations

(administrative code Title 158, Chapter 30); the Board's fine schedule (Title 158, Chapter 10); the

Oklahoma Lien Law (Title 42, Chapter 3); the NASCLA Contractors Guide to Business, Law and Project

Management; and the Oklahoma Workers' Compensation Act (Title 85A, Chapter 1) (CIB-bulletin, l. 2326).

Two conflict rules decide between competing sources: where a test question's answer could differ

because of conflicting information in the reference sources, a legal requirement such as a code, law or

regulation overrides any other reference; and where two legal requirements conflict, the state-specific

code, law or regulation overrides the national one (CIB-bulletin, l. 243).

The exam-room rules are printed with the reference lists: the examination is open book; references may

be highlighted, underlined and indexed beforehand but not written in before or during the session; no

additional papers may be brought in; references may be tabbed with permanent tabs only, temporary tabs

being removed before the examination begins; a downloaded reference must be spiral bound or

hole-punched and placed in a binder, or stapled in the left-hand corner; and a silent, non-printing,

non-programmable calculator is permitted (CIB-bulletin, l. 2186 and l. 2239).

8. What these documents do not state

The bulletin's plumbing reference list still names the 2018 edition of the International Plumbing

Code with Oklahoma Revisions while the commission's rule adopts the 2024 edition effective September

14, 2026. The repository's digest says as much: the bulletin is not yet backed by the IPC 2024 and no

2024 weights are published to date (BULLETIN.md, l. 28). Nothing here states that the examinations

are built on the 2024 edition.

No licence term, fee, continuing-education requirement, insurance or bond amount is stated by the

pieces filed here; the business and law topic list names Licensing Requirements and Required

Insurance/Bonds as subjects tested (CIB-bulletin, l. 2374), but those rules live in Oklahoma law, not

in the repository.

No Oklahoma statute text is held here. The pieces only name the statutes and administrative-code

chapters they draw on (CIB-bulletin, l. 2330), and no provision of them is reproduced or paraphrased

here.

No local licensing rule is held here, and the commission's own rule states only that other

jurisdictions may adopt appendices under 59 O.S. 1000.29 (748-rule, l. 61). Both pieces were

acquired, not reconstructed — the rule from the OUBCC's site, the bulletin from the PSI test-taker

site — and the sha256 of each file as filed is stated in the provenance note (PROVENANCE.md, l. 7).

Ready to test this chapter?

Practice with exam-aligned questions and timed simulations.

Start Practicing Free